Where to Buy SEG Electronics Relays in Pakistan
Looking to buy SEG Electronics relays? Pacific Engineering & Automation is the authorized SEG reseller in Pakistan - MRI3 and WIC1 g2 ranges, how ordering works, and what an enquiry should include.

A protection relay is a strange thing to shop for online. It costs a fraction of the transformer it protects, yet a wrong variant - the non-directional relay on a ring-fed feeder, the missing inrush restraint on a transformer bay - shows up only when the relay nuisance-trips a live 11 kV feeder or sits silent through a fault. Buyers searching for where to order SEG equipment are really asking two questions: where do genuine units come from, and who confirms the variant is right before money moves.
SEG Electronics (Kempen, Germany) builds the MRI3 and WIC1 g2 relay families used across Pakistani 11 kV and 33 kV distribution [1], and Pacific Engineering & Automation is the authorized SEG reseller in Pakistan. This guide covers what the range includes, how ordering actually works, and what to put in an enquiry so the quotation comes back right the first time.
Why the Authorized Route Matters for a 20-Year Asset
A protection relay is specified once and then expected to sit in a panel for two decades. Buying through the authorized channel gets you three things a marketplace listing cannot: a genuine unit with the manufacturer's warranty behind it, variant confirmation against the SEG datasheet before ordering, and local engineering support for settings and commissioning. SEG's relay families are tested against the IEC 60255 series - IEC 60255-1 for common requirements [2] and IEC 60255-151 for the over/under current functions and inverse-time curve families [3] - and those are the references a DISCO or NTDC tender will name, alongside the NEPRA Distribution Code that frames 11 kV and 33 kV protection schemes [4].
The SEG Range at a Glance
| Family | Role | Key point |
|---|---|---|
| MRI3 | Transformer and feeder protection | 50/51 + 50N/51N in one unit; variant per application |
| WIC1 g2 | Compact ring main units | Self-powered from the CT secondary; no auxiliary DC |
| WIP | Generator protection | Synchronous generator schemes |
| MRM3 | Motor protection | Thermal modelling |
| SIR | Bay control | Integrated control plus protection |
| PCD | Substation panels | Protection and control device |
Two families do most of the Pakistani distribution work. The MRI3 covers transformer and feeder bays with phase and earth-fault overcurrent in one housing; the WIC1 g2 is the compact-RMU relay that powers itself from the CT secondary, which is why Schneider Electric's Xiria GIS ring main units have shipped with the WIC1 family since 2002 [1].
Which MRI3 Variant Do You Need
"An MRI3" is not yet an orderable item - the variant carries the application:
- MRI3-IHE - transformer feeders: includes 2nd-harmonic restraint so the relay rides through magnetising inrush instead of tripping on energisation.
- MRI3-ITE(R) - thermal replica protection for generators, transformers, and cables.
- MRI3-IE - non-directional phase plus earth-fault overcurrent, the general feeder unit.
- MRI3-IRE / IRER - directional variants for ring-fed and parallel-source networks.
- MRI3-ICE - overcurrent with integrated circuit-breaker control.
All variants ship in door-mount and 19-inch rack housings with 1 A or 5 A CT secondary options and Modbus RTU communications; newer variants offer IEC 61850 [1]. The SEG protection relay specification guide covers the curve selection and coordination detail; note that protection relays are a different device class from the PLC interface relays used on control-panel outputs.
How Ordering Works: 4 Steps
The process is quotation-based, as all IEC 60255-class protection equipment is:
- Enquiry - you send the application, CT data, and functions needed (the checklist below).
- Variant confirmation - we match the requirement to the exact MRI3 or WIC1 variant against the SEG datasheet, and flag anything that does not fit.
- Quotation - a formal quote for the confirmed items; no prices are published because configuration drives cost.
- Delivery and support - genuine units with documentation, plus settings and commissioning assistance from our Karachi office.
Common Procurement Mistakes
The recurring errors when buying protection relays under IEC 60255:
- Ordering "an MRI3" without the variant. The suffix is the specification - an IE unit on a transformer bay has no inrush restraint and will nuisance-trip.
- Expecting differential protection from the MRI3 range. The family is overcurrent and earth-fault; transformer differential (ANSI 87T) needs a dedicated relay outside this range.
- Assuming IEC 61850 on every unit. Newer MRI3 variants carry it; older ones are Modbus RTU only - name the conformance requirement in the enquiry [1].
- Ignoring the CT secondary. 1 A and 5 A versions exist; the installed CT decides, and IEC 60255-151 accuracy applies at the rated input [3].
- Buying from unauthorized channels. A grey-market relay arrives with no variant check, no warranty path, and no one to call at commissioning.
What to Include in a SEG Enquiry: 6 Items
A SEG enquiry that quotes cleanly states:
- Application - transformer, feeder, generator, or motor bay, and whether the network is ring-fed
- CT data - ratio and secondary current (1 A or 5 A)
- Functions - e.g. 50/51 phase, 50N/51N earth fault, inrush restraint, thermal replica
- Curves - the IEC inverse-time family the coordination study uses (NI, VI, EI, LTI) [3]
- Communications - Modbus RTU or IEC 61850, and the SCADA it lands on
- Housing - door-mount or 19-inch rack, and the panel cutout if replacing an existing relay
Sourcing and Support in Pakistan
Pacific Engineering & Automation is the authorized SEG Electronics reseller in Pakistan, supplying the complete range - MRI3 variants, WIC1 g2, WIP, MRM3, SIR, and PCD - to DISCOs, K-Electric, NTDC grid projects, IPPs, and industrial substations, with protection-coordination support from our Karachi office.
To buy SEG relays or confirm the right variant for your bay, request a catalogue or quotation or contact our engineering team.
Field-derived case studies will be added to this post as Pacific Engineering & Automation accumulates engagement records. The current version is grounded in published specifications, regulatory documentation, and standards body references.
Sources
- SEG Electronics - official product portal
- IEC 60255-1:2022 - Measuring relays and protection equipment, Part 1: Common requirements
- IEC 60255-151:2009 - Functional requirements for over/under current protection
- NEPRA Distribution Code 2005 - Pakistan distribution regulatory framework (PDF)
Pacific Engineering & Automation
Need industrial equipment in Pakistan?
Authorized dealer and reseller for 16 international manufacturers. Karachi-based, serving Pakistan since 1995.